HP K

High-voltage battery

HP K.

Four to eight LFP battery modules in five specified stacked configurations. Match the selected voltage and communication settings to a compatible external inverter.

INVERTER
Compatible external inverter required
ENCLOSURE
IP20; IP54 optional
NOMINAL ENERGY
20.48–40.96 kWh
BATTERY VOLTAGE
204.8–409.6 V nominal DC
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Rated DC (kW)
HP2000K20.4820
HP2500K25.625
HP3000K30.7230
HP3500K35.8435
HP4000K40.9640

Battery-side DC ratings are not inverter AC output ratings. Confirm the inverter DC voltage window for the chosen module count.

ModelDimensions (mm)Approx. kg
HP2000K580 × 390 × 918 / L × W × H213
HP2500K580 × 390 × 1089 / L × W × H259.5
HP3000K580 × 390 × 1260 / L × W × H306
HP3500K580 × 390 × 1431 / L × W × H352.5
HP4000K580 × 390 × 1602 / L × W × H399

Communication: RS485 / CAN; Wi-Fi / Bluetooth optional
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C

Plan for your part of Vietnam.

Northern seasonal conditions, central rain exposure and a warm southern equipment space call for different site questions. Choose from the actual conditions around the battery, not a country-wide climate assumption.

Temperature:
Charge 0 to 55 °C; discharge −20 to 60 °C
ENCLOSURE
IP20; IP54 optional
01

Northern home · seasonal conditions

The north has a more distinct seasonal temperature pattern than the south.

For a dry indoor equipment alcove, compare the EU all-in-one with a battery-only format that matches the existing inverter. TR Pro's listed charging range starts at 0 °C; optional self-heating is not permission to charge below the confirmed limit.

What are the lowest and highest temperatures at the equipment location?
  • Can damp or condensation occur when seasons change?
  • Is an inverter already installed, and which battery voltage does it support?
02

Central home · rain-aware placement

Central Vietnam's rainfall timing differs from northern and southern regions.

Use a sheltered equipment area selected for the actual site. TR Pro and HP Ultra list IP66, but the reviewed literature does not establish flood or salt-spray suitability. Check the exact model's installation instructions and protection requirements.

Can wind-driven rain reach the wall or floor?
  • Is the property coastal, and is salt-air exposure relevant?
  • Which installation area stays dry and accessible for service?
03

Southern townhouse · warm equipment space

Southern Vietnam has a narrower seasonal temperature range than the north.

Allow for ventilation and service access in a dedicated equipment space. An EU integrated unit is IP21; do not treat it as an exposed outdoor product. A listed upper temperature limit does not promise full-power output in a hot enclosed cabinet.

Does the alcove collect heat or direct afternoon sun?
  • What temperature is observed while the room and equipment are in use?
  • Can the required ventilation and clearances be maintained?
Specifications
  • Choose architecture first: the EU and TA6000 all-in-one families include an inverter; TR, HP and TB battery-only families need a compatible external inverter.
  • Keep family limits separate. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. HP Ultra temperature limits require confirmation for the selected configuration; do not copy TR Pro's range onto it.
  • Match the enclosure to the actual placement. IP21, IP20, optional IP54 and IP66 are different source ratings; none supplies a salt-spray, condensation or flood guarantee in the reviewed literature.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

The original front/color-screen diagram shows four 5.12kWh sections; the family specification table spans four to eight modules. The connection/control face is not explicitly named rear. No separate GND, parallel COM1/COM2, INV CAN/RS485 or BMS debugging label is printed for this family, so none is imported from HP Ultra. The brochure supplies no pinout or installation/activation sequence.

Connection/control face - original labels
Connection/control face - original labelsCOM1 reserve, COM2 inverter connection, DC24V/AC230V activation and control switches.
Color-screen face
Color-screen faceFront view of the color-screen unit and stacked battery modules.
PDU connector and control detail
PDU connector and control detailTop-unit panel with connectors, indicators and switches.
Color-screen top-unit detail
Color-screen top-unit detailColor-screen area on the front of the top unit.
Separated module stack detail
Separated module stack detailSeparated battery modules showing their mating surfaces.

Know your interfaces.

Power connections

Negative Pole
Negative terminal as identified by the original leader line.
Positive Pole
Positive terminal as identified by the original leader line.
Battery Activation (DC24V)
A separately labelled DC24V battery-activation point in the original connection-face diagram.
Battery Activation (AC230V)
A separately labelled AC230V battery-activation point in the original connection-face diagram.

Communication

COM1: Reserve
COM1 is explicitly labelled Reserve.
COM2: Connect To Inverter
The source explicitly assigns the inverter connection to COM2.

Controls & indicators

Color Screen
Screen identified on the opposite, closed front-top face.
Air Switch
Switch/breaker labelled Air Switch on the connection/control face.
AC Switch
A separate control labelled AC Switch.
Alarm Lights
Alarm indicator group identified by the original leader line.
Running Lights
Running indicator group identified by the original leader line.
Adjustable Status Indicator
Feature caption on the separate status-line corner illustration on printed page 11.

Structure & mounting

PDU
The top unit identified as PDU above the battery sections; the source does not expand the abbreviation.
5.12kWh
Four repeated 5.12kWh sections are called out in the introduction diagram.
Chassis
Bottom chassis called out below the battery stack.

Source: Residential ESS brochure · PDF page 6 · printed pages 11-12